Teltone DS-100 Specifications
Electrical
Power Requirements
    DC Voltage 42-150 VDC
    AC Voltage (60 Hz) 90-120 VAC
    DC Current 650 mA max @ 42 VDC
    AC Current 270 mA max
Average Current Draw
    @ 42 VDC 500 mA
    @ 150 VDC 150 mA
    @ 90 VAC 210 mA  
    @ 120 VAC 170 mA  
Fuse Requirements 2 A, 250 V, Time Delay, Type 3AG
Alarm Contacts 125 VDC @ ¼ Amp
Emergency Interrupt 40 to 140 VRMS AC or DC voltage applied for at least 1 second
DC Power Out +12 VDC, -12 VDC
    maximum current draw + 12 VDC = 1.25 Amp
-12 VDC = 0.25 Amp
Serial Ports
    Interface RS-232
    Modem Port DTE/DE-9 male connector
    User Ports DCE/DE-9 female connector
    Local Maintenance Port DCE/DE-9 female connector
    All DTE and DCE connectors at potential.
Supported RS-232 Signals
    Pin Number
Signal Name:
Signal To:
           1
DCD
DTE
           2
RXD
DTE
           3
TXD
DCE
           4
DTR
DCE
           5
Ground
-----
           6
DSR
DTE
           7
RTS
DCE
           8
CTS
DTE
           9
RI
DTE*
           * Not on Local Maintenance Port
Watchdog Timer/Low Supply Voltage Detector
    Watchdog Time-out under 250 mS
Mechanical
    Dimensions
        Height 2.40 inches
        Length 9.75 inches
        Width 17.25 inches
19" or 23" rack or wall mounted and choice of flush or mid mount. Two units will mount into 3 standard rack heights.
Unit Weight 6 pounds
Housing Rolled aluminum, case at .
Environmental
Operating Temperature -20°C to +60°C
Storage Temperature -30°C to +70°C (3 day maximum)
Maximum Humidity 95% @ 40°C (non-condensing)
Electrostatic Discharge Immunity IEC801.2 level 4 ESD
Surge Withstand Capability ANSI/IEEE C37.901-1989
Vibration and Shock 47 CFR 68.302
Regulatory
FCC Part 15 Class A Complies
Product Reliability
Miminum MTBF (10) years or (87,660 hours)
Warranty Info The DS-100 unit is warranted for a period of 30 months. The warranty expiration date is evidenced by a label on each unit that states "Warranty expires on this date: Month-Day-Year"

 